Sign in →

Test Code TSI Thyroid-Stimulating Immunoglobulin, Serum

Test Down Notes

This test is temporarily unavailable. For additional details, see test update here.

Reporting Name

Thyroid-Stimulating Immunoglob, S

Useful For

Second-order testing for autoimmune thyroid disease, including:

-Differential diagnosis of etiology of thyrotoxicosis in patients with ambiguous clinical signs or contraindicated (eg, pregnant or breast-feeding) or indeterminate thyroid radioisotope scans

-Diagnosis of clinically suspected Graves disease (eg, extrathyroidal manifestations of Graves disease: endocrine exophthalmos, pretibial myxedema, thyroid acropachy) but normal thyroid function tests

-Determining the risk of neonatal thyrotoxicosis in a fetus of a pregnant female with active or past Graves disease

-Differential diagnosis of gestational thyrotoxicosis versus first-trimester manifestation or recurrence of Graves disease

-Assessing the risk of Graves disease relapse after antithyroid drug treatment

 

A combination of TSI / Thyroid-Stimulating Immunoglobulin, Serum and THYRO / Thyrotropin Receptor Antibody, Serum is useful as an adjunct in the diagnosis of unusual cases of hypothyroidism (eg, Hashitoxicosis).

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum


Ordering Guidance


This test is used for second-order testing for autoimmune thyroid disease.

 

For suspected cases of autoimmune hypothyroidism, the first-order testing is TPO / Thyroperoxidase Antibodies, Serum.

 

For suspected cases of autoimmune thyroid disease, first-order testing includes TPO and THYRO / Thyrotropin Receptor Antibody, Serum.



Specimen Required


Collection Container/Tube:

Preferred: Red top

Acceptable: Serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Specimen Minimum Volume

0.3 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Frozen (preferred) 60 days
  Refrigerated  7 days
  Ambient  24 hours

Reference Values

≤1.3 TSI index

Reference values apply to all ages.

Day(s) Performed

Monday through Friday

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

84445

LOINC Code Information

Test ID Test Order Name Order LOINC Value
TSI Thyroid-Stimulating Immunoglob, S 30567-2

 

Result ID Test Result Name Result LOINC Value
8634 Thyroid-Stimulating Immunoglob, S 30567-2

Interpretation

The sensitivity and specificity of an elevated thyroid-stimulating immunoglobulins (TSI) index for Graves disease diagnosis depends on whether patients have clinically active, untreated disease or disease treated with antithyroid drugs. Using a TSI index of 1.3 as the cutoff level in newly diagnosed, untreated patients, the sensitivity and specificity are higher than 90%. For a higher cutoff of 1.8, specificity approaches 100%, but sensitivity decreases somewhat. In patients with inactive or treated Graves disease the specificity is similar, while sensitivity is lower, ranging from 50% to 80%.

 

Significant neonatal thyrotoxicosis is likely if a pregnant woman with a history of Graves disease has a TSI index above 3.9 during the last trimester, regardless of her remission status. Lesser elevations are only occasionally associated with neonatal thyrotoxicosis. This is particularly relevant for women who have previously undergone thyroid-ablative therapy or are on active antithyroid drug treatment and therefore, no longer display biochemical or clinical evidence of thyrotoxicosis.

 

Gestational thyrotoxicosis, which is believed to be due to a combination of human chorionic gonadotropin cross-reactivity on the thyrotropin receptor (TSHR) and transient changes in thyroid hormone protein binding, is not associated with an elevated TSI index. Finding an elevated TSI index in this setting suggests underlying Graves disease.

 

An elevated TSI index at the conclusion of a course of anti-thyroid drug treatment is highly predictive of relapse of Graves disease. However, the converse, a normal TSI index, is not predictive of prolonged remission.

 

In patients with thyroid function tests that fluctuate between hypo- and hyperthyroidism or vice versa, a clearly elevated TSHR-antibody level (>25%) and a simultaneous TSI index that is normal or only minimally elevated (1.3-1.8) suggest a diagnosis of possible Hashitoxicosis.

Clinical Reference

1. Grebe SKG. Thyroid disease. In: King RA, Rotter JI, Motulsky AG, eds. The Genetic Basis of Common Diseases. 2nd ed. Oxford University Press; 2002:397-430

2. Ross DS, Burch HB, Cooper DS, et al. 2016 American Thyroid Association Guidelines for Diagnosis and Management of Hyperthyroidism and Other Causes of Thyrotoxicosis. Thyroid. 2016;26(10):1343-1421. doi:10.1089/thy.2016.0229

3. Kahaly GJ, Bartalena L, Hegedus L, Leenhardt L, Poppe K, Pearce SH. 2018 European Thyroid Association Guideline for the Management of Graves' Hyperthyroidism. Eur Thyroid J. 2018;7(4):167-186

4. Lytton SD, Schluter A, Banga PJ. Functional diagnostics for thyrotropin hormone receptor autoantibodies: bioassays prevail over binding assays. Front Biosci (Landmark Ed). 2018;23(11):2028-2043

5. De Leo S, Pearce EN. Autoimmune thyroid disease during pregnancy. Lancet Diabetes Endocrinol. 2018;6(7):575-586

6. Stan MN, Algeciras-Schimnich A, Murthy V, Thapa P, Araki N. Diagnostic utility of a new assay for thyroid stimulating immunoglobulins in Graves' disease and thyroid eye disease. Thyroid. 2022;32(2):170-176. doi:10.1089/thy.2021.0299

Report Available

2 to 6 days

Method Name

Recombinant Bioassay

Forms

If not ordering electronically, complete, print, and send a General Request (T239) with the specimen.