Test Code PRCON Protein, Total, Random, Urine
Specimen Required
Only orderable as part of a profile. For more information see:
ORTHP / Orthostatic Proteinuria, Random, Urine
Patient Preparation: Specimens should be collected before fluorescein is given or not collected until at least 24 hour later.
Container/Tube: Plastic, 5-mL tube
Specimen Volume: 4 mL
Collection Instructions:
1. This is a nighttime (supine) collection.
2. Void immediately prior to lying down.
3. Collect an 8-hour (nighttime) urine specimen.
4. Upon awaking in the morning, the patient should immediately void into the specimen cup.
4. No preservative.
5. Invert well before taking 4-mL (maximum) aliquot.
Useful For
Measurement of total protein for the assessment of orthostatic proteinuria
Method Name
Only orderable as part of a profile. For more information see:
ORTHP / Orthostatic Proteinuria, Random, Urine
Turbidimetry
Reporting Name
Protein, Total, Random, USpecimen Type
UrineSpecimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Urine | Refrigerated (preferred) | 14 days | |
Frozen | 30 days | ||
Ambient | 24 hours |
Reference Values
Not established
Interpretation
First-morning urine protein-to-creatinine ratio of less than 0.20 mg/mg creatinine supports the diagnosis of orthostatic proteinuria, while a result greater than 0.20 mg/mg creatinine does not support this diagnosis.
Further investigation into other etiologies for proteinuria may be warranted.
Clinical Reference
1. Brunzel N: Chemical examination of urine. In: Fundamentals of Urine and Body Fluids. 4th ed. Saunders; 2018:92-94
2. Wilson DM, Anderson RL: Protein-osmolality ratio for the quantitative assessment of proteinuria from a random urinalysis sample. Am J Clin Pathol. 1993 Oct;100(4):419-424
3. Morgenstern BZ, Butani L, Wollan P, Wilson DM, Larson TS: Validity of protein-osmolality versus protein-creatinine ratios in the estimation of quantitative proteinuria from random samples of urine in children. Am J Kidney Dis. 2003 Apr;41(4):760-766
4. Rinehart BK, Terrone DA, Larmon JE, Perry KG Jr, Martin RW, Martin JN Jr: A 12-hour urine collection accurately assesses proteinuria in hospitalized hypertensive gravida. J Perinatol. 1999 Dec;19(8 Pt 1):556-558
5. Adelberg AM, Miller J, Doerzbacher M, Lambers DS: Correlation of quantitative protein measurements in 8-, 12-, and 24-hour urine samples for diagnosis of preeclampsia. Am J Obstet Gynecol. 2001 Oct;185(4):804-807
6. Robinson RR: Isolated proteinuria in asymptomatic patients. Kidney Int. 1980 Sep;18(3):395-406
7. Dube J, Girouard J, Leclerc P, Douville P: Problems with the estimation of urine protein by automated assays. Clin Biochem. 2005 May;38(5):479-485
8. Koumantakis G, Wyndham L: Fluorescein interference with urinary creatinine and protein measurements. Clin Chem. 1991 Oct;37(10 Pt 1):1799
9. Lamb EJ, Jones GRD: Kidney function tests. In: Rifai N, Horvath AR, Wittwer CT, eds. Tietz Textbook of Clinical Chemistry and Molecular Diagnostics. 6th ed. Elsevier; 2018:479-517
Day(s) Performed
Monday through Sunday
Report Available
Same day/1 to 7 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
84156
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
PRCON | Protein, Total, Random, U | 2888-6 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
PRCON | Protein, Total, Random, U | 2888-6 |