Test Code POC ACT Point of Care (POC) Activated Clotting Time
Methodology
i-STAT® Cartridge
Specimen Requirements
1mL of whole blood drawn into a plastic syringe
Day(s) Test Set Up
Monday through Sunday
Reference Values
ISTAT ONLY
Procedure/Qualifier | Target/Range |
---|---|
Neuroradiology/target range patient specific and subject to physician’s discretion during the case | 1.5 – 2.0 times the baseline value102-146 seconds |
Electrophysiology (EP) | 200 – 400 seconds |
Extracorporeal Membrane Oxygenation (ECMO)/target range procedure determined for each patient in the physician’s order (Cardiohelp) | 200 – 220 seconds with an upper limit of 240 seconds (Usually measure PTT of 40 secs) |
Cardiac catheterization/target range procedure and patient-specific interventional catheterization (This is titled Interventional Catherization Patient on the EMR result interpretation) | 170 – 230 seconds for patients receiving platelet GpIIb-IIIa inhibitors and 200 – 240 seconds for patients not receiving platelet Gpllb – IIIa inhibitors |
Cardiac surgery/target ranges may vary with procedure: | |
Baseline – 90 – 130 seconds Heparin Bolus – > 400 seconds On Cardiopulmonary bypass (CPB) regardless of the surgical procedure – greater than 450 seconds Off CPB Coronary Artery Bypass Graft (CABG) - greater than 400 seconds Therapeutic bivalirudin for CPB- Initial ACT, greater than 400 seconds |
Performing Laboratory
Beebe Healthcare Laboratory
Performing Location
Margaret H. Rollins Laboratory