Test Code PC2TC Purkinje Cell Cytoplasmic Antibody Type 2 (PCA-2) Titer, Spinal Fluid


Ordering Guidance


Serum is preferred. Spinal fluid testing is particularly useful when interfering antibodies are present in the serum.



Specimen Required


Only orderable as a reflex. For more information see:

-DMC2 / Dementia, Autoimmune/Paraneoplastic Evaluation, Spinal Fluid

-ENC2 / Encephalopathy, Autoimmune/Paraneoplastic Evaluation, Spinal Fluid

-EPC2 / Epilepsy, Autoimmune/Paraneoplastic Evaluation, Spinal Fluid

-MDC2 / Movement Disorder, Autoimmune/Paraneoplastic Evaluation, Spinal Fluid

-MAC1 / Myelopathy, Autoimmune/Paraneoplastic Evaluation, Spinal Fluid

 

Container/Tube: Sterile vial

Specimen Volume: 4 mL


Useful For

Evaluating patients who present with a subacute neurological disorder of undetermined etiology and have risk factors for lung cancer

 

Reporting an end titer result from spinal fluid specimens

Testing Algorithm

If the indirect immunofluorescence pattern suggests Purkinje cell cytoplasmic antibody type 2 (PCA-2), then this test will be performed at an additional charge.

Method Name

Only orderable as a reflex. For more information see:

DMC2 / Dementia, Autoimmune/Paraneoplastic Evaluation, Spinal Fluid

ENC2 / Encephalopathy, Autoimmune/Paraneoplastic Evaluation, Spinal Fluid

EPC2 / Epilepsy, Autoimmune/Paraneoplastic Evaluation, Spinal Fluid

MDC2 / Movement Disorder, Autoimmune/Paraneoplastic Evaluation, Spinal Fluid

MAC1 / Myelopathy, Autoimmune/Paraneoplastic Evaluation, Spinal Fluid

 

Indirect Immunofluorescence Assay (IFA)

Reporting Name

PCA-2 Titer, CSF

Specimen Type

CSF

Specimen Minimum Volume

2 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
CSF Refrigerated (preferred) 28 days
  Frozen  28 days
  Ambient  72 hours

Reference Values

Only orderable as a reflex. For more information see:

-DMC2 / Dementia, Autoimmune/Paraneoplastic Evaluation, Spinal Fluid

-ENC2 / Encephalopathy, Autoimmune/Paraneoplastic Evaluation, Spinal Fluid

-EPC2 / Epilepsy, Autoimmune/Paraneoplastic Evaluation, Spinal Fluid

-MDC2 / Movement Disorder, Autoimmune/Paraneoplastic Evaluation, Spinal Fluid

-MAC1 / Myelopathy, Autoimmune/Paraneoplastic Evaluation, Spinal Fluid

 

<1:2

Neuron-restricted patterns of IgG staining that do not fulfill criteria for Purkinje cell cytoplasmic antibody type 2  may be reported as "unclassified antineuronal IgG." Complex patterns that include non-neuronal elements may be reported as "uninterpretable."

Interpretation

A positive value (at 1:2 dilution or higher) is consistent with neurological autoimmunity and justifies a thorough search for a lung cancer, particularly small-cell carcinoma. The cancers are usually limited in metastasis. An extrapulmonary primary small-cell carcinoma (eg, skin, breast, larynx, cervix, prostate) should be considered.

 

Purkinje cell autoantibody type 2 is found in less than 2% of patients with uncomplicated small-cell lung carcinoma.

Clinical Reference

1. Galanis E, Frytak S, Rowland KM, et al: Neuronal autoantibody titers in the course of small-cell lung carcinoma and platinum-associated neuropathy. Cancer Immunol Immunother 1999 May-June;48(2-3):85-90

2. Vernino S, Lennon VA: New Purkinje cell antibody (PCA-2): marker of lung cancer-related neurological autoimmunity. Ann Neurol 2000 Mar;47(3):297-305

3. McKeon A, Tracy JA, Pittock SJ, Parisi JE, Klein CJ, Lennon VA. Purkinje cell cytoplasmic autoantibody type 1 accompaniments: the cerebellum and beyond. Arch Neurol. 2011 Oct;68(10):1282-9. doi: 10.1001/archneurol.2011.128

4. Hetzel DJ, Stanhope CR, O'Neill BP, Lennon VA: Gynecologic cancer in patients with subacute cerebellar degeneration predicted by anti-Purkinje cell antibodies and limited in metastatic volume. Mayo Clin Proc. 1990 Dec;65(12):1558-15635

5. Horta ES, Lennon VA, Lachance DH, et al: Neural autoantibody clusters aid diagnosis of cancer. Clin Cancer Res. 2014 Jul;20(14):3862-3869

Day(s) Performed

Monday through Sunday

Report Available

6 to 8 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

86256

LOINC Code Information

Test ID Test Order Name Order LOINC Value
PC2TC PCA-2 Titer, CSF 94364-7

 

Result ID Test Result Name Result LOINC Value
43447 PCA-2 Titer, CSF 94364-7