Test Code MDNS Methadone and Metabolites, Serum
Useful For
Compliance monitoring of methadone
Assessment of methadone toxicity
Method Name
Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)
Reporting Name
Methadone and Metabolite, SSpecimen Type
Serum RedSpecimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Container/Tube: Red top (Serum gel/SST are not acceptable)
Submission Container/Tube: Plastic vial
Specimen Volume: 1.0 mL
Collection Instructions: Within 2 hours of collection, centrifuge and aliquot serum into a plastic vial.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum Red | Refrigerated (preferred) | 28 days | |
Frozen | 28 days | ||
Ambient | 14 days |
Reference Values
Not established
Interpretation
There is a significant overlap between the reported therapeutic and toxic concentrations of methadone in blood specimens.
Clinical Reference
1. Langman LJ, Bechtel LK, Holstege CP. Clinical toxicology. In: Rifai N, Chiu RWK, Young I, Burnham CAD, Wittwer CT, eds. Tietz Textbook of Laboratory Medicine. 7th ed. Elsevier; 2023:chap 43
2. Yaksh TL, Wallace MS. Opioids, analgesia, and pain management. In: Brunton LL, Chabner BA, Knollmann BC, eds. Goodman and Gilman's The Pharmacological Basis of Therapeutics. 12th ed. McGraw-Hill Book Company; 2011:chap 18
3. Baselt RC. Disposition of Toxic Drugs and Chemical in Man. 9th ed. Biomedical Publications; 2011:1021-1025
Day(s) Performed
Tuesday, Thursday
Report Available
3 to 5 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
80299
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
MDNS | Methadone and Metabolite, S | 96602-8 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
36309 | Methadone | 3772-1 |
36310 | EDDP | 60071-8 |
Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.Forms
If not ordering electronically, complete, print, and send a Therapeutics Test Request (T831) with the specimen.