Sign in →

Test Code MACE Mace, IgE, Serum

Reporting Name

Mace, IgE

Useful For

Establishing the diagnosis of an allergy to mace

 

Defining the allergen responsible for eliciting signs and symptoms

 

Identifying allergens:

-Responsible for allergic response and/or anaphylactic episode

-To confirm sensitization prior to beginning immunotherapy

-To investigate the specificity of allergic reactions to insect venom allergens, drugs, or chemical allergens

 

Testing for IgE antibodies is not useful in patients previously treated with immunotherapy to determine if residual clinical sensitivity exists, or in patients in whom the medical management does not depend upon identification of allergen specificity.

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum


Ordering Guidance


For a listing of allergens available for testing, see Allergens - Immunoglobulin E (IgE) Antibodies



Specimen Required


Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL for every 5 allergens requested

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Specimen Minimum Volume

For 1 allergen: 0.3 mL
More than 1 allergen: (0.05 mL x number of allergens) + 0.25 mL dead space

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 14 days
  Frozen  90 days

Reference Values

Class

IgE kU/L

Interpretation

0

<0.10

Negative

0/1

0.10-0.34

Borderline/equivocal

1

0.35-0.69

Equivocal

2

0.70-3.49

Positive

3

3.50-17.4

Positive

4

17.5-49.9

Strongly positive

5

50.0-99.9

Strongly positive

6

≥100

Strongly positive

Reference values apply to all ages.

Day(s) Performed

Monday through Friday

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

86003

LOINC Code Information

Test ID Test Order Name Order LOINC Value
MACE Mace, IgE 15280-1

 

Result ID Test Result Name Result LOINC Value
MACE Mace, IgE 15280-1

Interpretation

Detection of IgE antibodies in serum (class 1 or greater) indicates an increased likelihood of allergic disease as opposed to other etiologies and defines the allergens that may be responsible for eliciting signs and symptoms.

 

The level of IgE antibodies in serum varies directly with the concentration of IgE antibodies expressed as a class score or kU/L.

Clinical Reference

Homburger HA, Hamilton RG: Allergic diseases. In: McPherson RA, Pincus MR, eds. Henry's Clinical Diagnosis and Management by Laboratory Methods. 23rd ed. Elsevier; 2017:1057-1070

Report Available

Same day/1 to 3 days

Method Name

Fluorescence Enzyme Immunoassay (FEIA)

Forms

If not ordering electronically, complete, print, and send an Allergen Test Request (T236) with the specimen.