Test Code KCSF Immunoglobulin Kappa Free Light Chain, Spinal Fluid


Ordering Guidance


For evaluation of multiple sclerosis, Multiple Sclerosis (MS) Profile, Serum and Spinal Fluid, SFIG/ Cerebrospinal Fluid IgG Index Profile, Serum and Spinal Fluid in conjunction with OLIG / Oligoclonal Banding, Serum and Spinal Fluid are still available as individually orderable tests.

 

In addition, a multiple sclerosis profile (MSP3 / Multiple Sclerosis (MS) Profile, Serum and Spinal Fluid) is available. This profile starts with immunoglobulin kappa free light chain testing. When that is borderline or elevated, additional testing for oligoclonal banding will be performed and results interpreted accordingly.



Specimen Required


Specimen Type: Spinal fluid

Container/Tube: Sterile vial

Specimen Volume: 1 mL

Collection Instructions: Label specimen as spinal fluid.


Useful For

Diagnosing multiple sclerosis and other demyelinating conditions

 

Evaluating patients who present with a clinically isolated syndrome in which the patient reports symptoms (headaches, optic neuritis, fatigue, and many others, depending on the disease location) characteristic of inflammation and demyelination of the central nervous system

 

Recommended in cases where the imaging findings are atypical and in populations in which multiple sclerosis is less common (eg, children, older individuals, or non-White populations)

 

The test is not useful when a clear diagnosis is already known because a positive result does not correlate with severity of the disease or disease outcomes.

Method Name

Nephelometry

Reporting Name

Kappa Free Light Chain, CSF

Specimen Type

CSF

Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
CSF Frozen (preferred) 28 days
  Refrigerated  72 hours
  Ambient  24 hours

Reference Values

Medical Decision Point: 0.1000 mg/dL

Positive: ≥0.1000 mg/dL

Borderline: 0.0600 mg/dL-0.0999 mg/dL

Negative <0.0600 mg/dL

Interpretation

When a result is less than 0.0600 mg/dL, the kappa free light-chain concentration measured in cerebrospinal fluid (CSF) is lower than the threshold associated with demyelinating disease. This is a negative result. Clinical correlation is recommended.

 

When result is between 0.0600 and 0.0999 mg/dL, this is a borderline result. These findings are not specific for multiple sclerosis (MS) because CSF-specific immunoglobulin synthesis may also be detected in patients with other neurologic diseases (infectious, inflammatory, cerebrovascular, autoimmune, and paraneoplastic). If clinically indicated, consider additional CSF testing such as oligoclonal banding by isoelectric focusing and CSF IgG index.

 

When result is greater than or equal to 0.1000 mg/dL, the kappa free light chain concentration measured in CSF is at or greater than the threshold associated with demyelinating disease. This is a positive result. These findings, however, are not specific for MS because CSF-specific immunoglobulin synthesis may also be detected in patients with other neurologic diseases (infectious, inflammatory, cerebrovascular, autoimmune, and paraneoplastic). If clinically indicated, consider additional CSF testing such as oligoclonal banding by isoelectric focusing and CSF IgG index.

 

A Mayo Clinic study published in 2018 with 325 patients suggested that a kappa free light-chain concentration in CSF greater than or equal to 0.06 mg/dL has 92.5% clinical sensitivity in the diagnosis of multiple sclerosis.(1)

 

A second, larger Mayo Clinic study with 1355 patients published in 2021 showed that a kappa CSF concentration greater than or equal to 0.06 mg/dL had approximately 89% sensitivity. When the kappa level was greater than or equal to 0.1 mg/dL, it had similar sensitivity (87%) to the finding of two unique CSF oligoclonal bands (89%).(2)

Clinical Reference

1. Gurtner KM, Shosha E, Bryant SC, et al: CSF free light chain identification of demyelinating disease: comparison with oligoclonal banding and other CSF indexes. Clin Chem Lab Med. 2018 Jun;56(7):1071-1080

2. Saadeh RS, Bryant SC, McKeon A, et al: CSF kappa free light chains: Cutoff validation for diagnosing multiple sclerosis. Mayo Clin Proc. 2022 Apr;97(4):738-751. doi: 10.1016/j.mayocp.2021.09.014

3. Thompson AJ, Banwell BL, Barkhof F, et al: Diagnosis of multiple sclerosis: 2017 revisions of the McDonald criteria. The Lancet Neurology. 2018 Feb;17(2):162-173

4. Saadeh R, Pittock S, Bryant S, et al: CSF kappa free light chains as a potential quantitative alternative to oligoclonal bands in multiple sclerosis. American Academy of Neurology Annual Meeting. Philadelphia, PA. 2019

5. Awad A, Hemmer B, Hartung HP, Kieseier B, Bennett JL, Stuve O: Analyses of cerebrospinal fluid in the diagnosis and monitoring of multiple sclerosis. J Neuroimmunol. 2010;219:1-7

6. Hassan-Smith G, Durant L, Tsentemeidou A, et al: High sensitivity and specificity of elevated cerebrospinal fluid kappa free light chains in suspected multiple sclerosis. J Neuroimmunol. 2014;276(1-2):175-179

7. Presslauer S, Milosavljevic D, Brucke T, et al: Elevated levels of kappa free light chains in CSF support the diagnosis of multiple sclerosis. J Neurol. 2008 Oct;255(10):1508-1514

8. Presslauer S, Milosavljevic D, Brucke T, et al: Validation of kappa free light chains as a diagnostic biomarker in multiple sclerosis and clinically isolated syndrome: a multicenter study. Mult Scler. 2016 Apr;22(4):502-10

9. Presslauer S, Milosavljevic D, Hubl W, Parigger S, Schneider-Koch G, Bruecke T: Kappa free light chains: Diagnostic and prognostic relevance in MS and CIS. PLoS One. 2014 Feb;9(2):e89945

10. Makshakov G, Nazarov V, Kochetova O, Surkova E, Lapin S, Evdoshenko E: Diagnostic and prognostic value of the cerebrospinal fluid concentration of immunoglobulin free light chains in clinically isolated syndrome with conversion to multiple sclerosis. PLoS One. 2015 Nov;10(11):e0143375

Day(s) Performed

Monday through Friday

Report Available

1 to 3 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test has been modified from the manufacturer's instructions. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

83521

LOINC Code Information

Test ID Test Order Name Order LOINC Value
KCSF Kappa Free Light Chain, CSF 48774-4

 

Result ID Test Result Name Result LOINC Value
KCSF Kappa Free Light Chain, CSF 48774-4