Sign in →

Test Code HLA-A29 Detection HLA-A29 Detection

Important Note

  • MUST be ordered as a .Mayo Miscellaneous Test
  • Use code ZW121 and use name of test HLA-A29 Determination
  • MUST put in Order NOTES in Lab Compute the statement "Versiti of of Wisconsin #2274"

Methodology

PCR-rSSO

Specimen Requirements

Recommended: 5-14 mL ACD(yellow top) Tube or EDTA (Lavendar top) Tube

Minimum Required: 5 mL Whole Blood (ACD or EDTA)

 

Specimen Stability = 14 days at Ambient Temperature

Performing Laboratory

Versiti of Wisconsin (Formerly Blood Center of Wisconsin)

Sent out to Mayo Medical Lab who then sends it to Versiti of Wisconsin