Test Code FWING Wingscale (Atriplex Canescens) IgE
Specimen Required
Specimen Type: Serum
Container/Tube: Red Top
Specimen Volume: 0.5 mL
Collection Instructions: Draw blood in a plain red-top tube(s), serum gel tube(s) is acceptable. Spin down and send 0.5 mL of serum refrigerated in a plastic vial.
Method Name
Enzyme Immunoassay (EIA)
Reporting Name
Wingscale (Atriplex canescens) IgESpecimen Type
SerumSpecimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 28 days | |
Frozen | 365 days | ||
Ambient | 28 days |
Reference Values
<0.35 kU/L
Interpretation
IgE (kU/L) |
Comment |
|
0 |
<0.35 |
Below Detection |
1 |
0.35-0.69 |
Low Positive |
2 |
0.70-3.49 |
Moderate Positive |
3 |
3.50-17.49 |
Positive |
4 |
17.50-49.99 |
Strong Positive |
5 |
≥49.99 |
Very Strong Positive |
Day(s) Performed
Monday through Friday
Report Available
4 to 7 daysPerforming Laboratory
Eurofins ViracorTest Classification
This test was developed and its performance characteristics determined by Eurofins Viracor . It has not been cleared or approved by the U.S. Food and Drug Administration.CPT Code Information
86003
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
FWING | Wingscale (Atriplex canescens) IgE | 7779-2 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
Z4028 | Wingscale (Atriplex canescens) IgE | 7779-2 |
Z4029 | CLASS | 102664-0 |