Test Code FNAOP Fine-Needle Aspiration (FNA)/Office Procedure
Methodology
If microbiology studies are required, Microbiology instructions will supercede the cytology instructions. Microbiology studies must be ordered in clinical laboratory computer or on a Request for Microbiology Testing Form.
Specimen Requirements
Supplies for fine needle aspiration are available from Beebe Community Laboratory. Call pathologist performed palpable mass fine-needle aspiration service at 302-645-3595 to schedule.
Container/Tube: 2 air-dried direct smears
Specimen Volume: See Container/Tube.
Forms: Request for Surgical Pathology and Non-Gyn Cytology
Collection Instructions:
1. Follow universal precautions.
2. Perform FNA, first pass. It is suggested to
sample lesion in 3 directions.
3. Prepare 2 properly labeled, air-dried direct smears.
4. Rinse needle and syringe using Cytolyt fixative fluid in a properly labeled, red-top tube.
5. Discard all needles and syringes.
6. Submit slide, tube, and request form in a biohazard bag to Beebe
Community Laboratory.
The above process may be repeated several times. Use new slide for each pass and indicate pass # on label. If sampling a different mass, use new tube of CytoLyt fixative.
Day(s) Test Set Up
Monday through Friday
Reference Values
An interpretive report will be provided.
Test Classification and CPT Coding
88173
Performing Laboratory
Beebe Healthcare Laboratory
Performing Location
Beebe Healthcare Laboratory
Specimen Transport Temperature
Ambient