Test Code F2_IS Factor II Inhibitor Screen, Plasma
Method Name
Only orderable as part of a profile. For more information see:
2INHE / Factor II Inhibitor Evaluation, Plasma
ALBLD / Bleeding Diathesis Profile, Limited, Plasma
APROL / Prolonged Clot Time Profile, Plasma
Optical Clot-Based
Reporting Name
Factor II Inhib ScrnSpecimen Type
Plasma Na CitSpecimen Minimum Volume
2 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Plasma Na Cit | Frozen | 14 days |
Reference Values
Only orderable as part of a profile. For more information see:
2INHE / Factor II Inhibitor Evaluation, Plasma
ALBLD / Bleeding Diathesis Profile, Limited, Plasma
APROL / Prolonged Clot Time Profile, Plasma
Negative
Day(s) Performed
Monday through Friday
Report Available
1 to 3 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test has been modified from the manufacturer's instructions. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
85335
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
F2_IS | Factor II Inhib Scrn | 96454-4 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
7806 | Factor II Inhib Scrn | 96454-4 |
Ordering Guidance
Specimen Required
Only orderable as part of a profile. For more information see:
2INHE / Factor II Inhibitor Evaluation, Plasma
ALBLD / Bleeding Diathesis Profile, Limited, Plasma
APROL / Prolonged Clot Time Profile, Plasma
For information see Coagulation Guidelines for Specimen Handling and Processing.
Useful For
Detecting the presence of a specific factor inhibitor directed against coagulation factor II
Interpretation
When testing is complete, if factor activity results fall within clinically normal ranges, an interpretive comment will be provided noting that inhibitor testing was not indicated and, therefore, not performed. If factor activity indicates the performance of inhibitor screen testing, an interpretive comment will be provided noting the presence or absence of a factor II inhibitor.
Clinical Reference
1. Bowie EJW, Thompson JH Jr, Didisheim P, Owen CA Jr. Mayo Clinic Laboratory Manual of Hemostasis. WB Saunders Company; 1971:111-115
2. Kottke-Marchant K. Laboratory Hematology Practice. Wiley Blackwell Publishing, 2012
3. Hoffman R, Benz EJ Jr, Silberstein, et al. Hematology: Basic Principles and Practice. 7th ed. Elsevier; 2018