Test Code EBVQN Epstein-Barr Virus DNA Detection and Quantification, Plasma
Shipping Instructions
1. Ship specimen frozen on dry ice only.
2. If shipment will be delayed for more than 24 hours, freeze plasma at -20 to -80° C (up to 84 days) until shipment on dry ice.
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Lavender top (EDTA)
Submission Container/Tube: Plastic vial
Specimen Volume: 1.5 mL
Collection Instructions:
1. Centrifuge blood collection tube per manufacturer's instructions (eg, centrifuge within 2 hours of collection for BD Vacutainer tubes).
2. Aliquot plasma into plastic vial.
Useful For
Diagnosis of Epstein-Barr virus (EBV)-associated infectious mononucleosis in individuals with equivocal or discordant EBV serologic marker test results
Diagnosis of post-transplant lymphoproliferative disorders (PTLD), especially in EBV-seronegative organ transplant recipients receiving antilymphocyte globulin for induction immunosuppression and OKT-3 treatment for early organ rejection
Monitoring progression of EBV-associated PTLD in organ transplant recipients
This test should not be used to screen asymptomatic patients.
Method Name
Real-Time Polymerase Chain Reaction (RT-PCR)
Reporting Name
EBV DNA Detect/Quant, PSpecimen Type
Plasma EDTASpecimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Plasma EDTA | Frozen (preferred) | 84 days | |
Refrigerated | 6 days |
Reference Values
Undetected
Interpretation
The quantification range of this assay is 35 to 100,000,000 IU/mL (1.54 log to 8.00 log IU/mL), with a limit of detection (95% detection rate) at 19 IU/mL.
Increasing levels of Epstein-Barr virus (EBV) DNA in serial plasma specimens of a given organ transplant recipient may indicate possible development of post-transplant lymphoproliferative disorder (PTLD).
An "Undetected" result indicates that EBV DNA is not detected in the plasma specimen (see Cautions). If clinically indicated, repeat testing in 1 to 2 months is recommended.
A result of "<35 IU/mL" indicates that the EBV DNA level present in the plasma specimen is below 35 IU/mL (1.54 log IU/mL), and the assay cannot accurately quantify the EBV DNA present below this level.
A quantitative value (reported in IU/mL and log IU/mL) indicates the EBV DNA level (ie, viral load) present in the plasma specimen.
A result of ">100,000,000 IU/mL" indicates that the EBV DNA level present in the plasma specimen is above 100,000,000 IU/mL (8.00 log IU/mL), and this assay cannot accurately quantify the EBV DNA present above this level.
An "Inconclusive" result indicates that the presence or absence of EBV DNA in the plasma specimen could not be determined with certainty after repeat testing in the laboratory, possibly due to polymerase chain reaction inhibition or presence of interfering substance. Submission of a new specimen for testing is recommended if clinically indicated.
Clinical Reference
1. San-Juan R, Comoli P, Caillard S, et al: Epstein-Barr virus-related post-transplant lymphoproliferative disorder in solid organ transplant recipients. Clin Microbiol Infect. 2014 Sep;20(Suppl 7):109-118. doi: 10.1111/1469-0691.12534
2. Jiang SY, Yang JW, Shao JB, Liao XL, Lu ZH, Jiang H: Real-time polymerase chain reaction for diagnosing infectious mononucleosis in pediatric patients: A systematic review and meta-analysis. J Med Virol. 2016 May;88(5):871-876. doi: 10.1002/jmv.24402
3. Allen UD, Preiksaitis JK, AST Infectious Diseases Community of Practice: Post-transplant lymphoproliferative disorders, Epstein-Barr virus infection, and disease in solid organ transplantation: Guidelines from the American Society of Transplantation Infectious Diseases Community of Practice. Clin Transplant. 2019 Sep;33(9):e13652. doi: 10.1111/ctr.13652
4. Kimura H, Kwong YL: EBV Viral Loads in diagnosis, monitoring, and response assessment. Front Oncol. 2019 Feb 12;9:62. doi: 10.3389/fonc.2019.00062
Day(s) Performed
Monday through Saturday
Report Available
1 to 3 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
87799
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
EBVQN | EBV DNA Detect/Quant, P | 43730-1 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
615297 | EBV DNA Detect/Quant, P | 43730-1 |
Forms
If not ordering electronically, complete, print, and send 1 of the following forms with the specimen:
-Microbiology Test Request (T244)
-General Request (T239)
-Renal Diagnostics Test Request (T830)