Test Code C3FX C3 Complement, Functional, Serum
Reporting Name
C3 Complement, Functional, SUseful For
Diagnosis of C3 deficiency
Investigation of a patient with undetectable total complement level
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
Serum RedOrdering Guidance
The total complement assay (COM / Complement, Total, Serum) should be used as a screen for suspected complement deficiencies before ordering individual complement component assays. A deficiency of an individual component of the complement cascade will result in an undetectable total complement level.
Specimen Required
Patient Preparation: Fasting preferred
Supplies: Sarstedt 5 mL Aliquot Tube (T914)
Collection Container/Tube: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions:
1. Immediately after specimen collection, place the tube on wet ice.
2. Centrifuge and aliquot serum into plastic vial.
3. Immediately freeze specimen.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum Red | Frozen | 14 days |
Reference Values
21-50 U/mL
Day(s) Performed
Monday through Friday
Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
86161
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
C3FX | C3 Complement, Functional, S | 87723-3 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
C3FX | C3 Complement, Functional, S | 87723-3 |
Interpretation
Low levels of complement may be due to inherited deficiencies, acquired deficiencies, or due to complement consumption (eg, as a consequence of infectious or autoimmune processes).
Absent C3 levels in the presence of other normal complement values are consistent with a C3 deficiency.
Clinical Reference
1. Davis ML, Austin C, Messmer BL, et al: IFCC-standardization pediatric reference intervals for 10 serum proteins using the Beckman Array 360 system. Clin Biochem. 1996;29(5):489-492
2. Gaither TA, Frank MM: Complement. In: Henry JB, ed. Clinical Diagnosis and Management by Laboratory Methods. 17th ed. WB Saunders Company; 1984:879-892
3. O'Neil KM: Complement deficiency. Clin Rev Allergy Immunol. 2000;19:83-108
4. Frank MM: Complement deficiencies. Pediatr Clin North Am. 2000;47(6):1339-1354
5. Brodszki N, Frazer-Abel A, Grumach AS, et al: European Society for Immunodeficiencies (ESID) and European Reference Network on Rare Primary Immunodeficiency, Autoinflammatory and Autoimmune Diseases (ERN RITA) Complement Guideline: Deficiencies, diagnosis, and management. J Clin Immunol. 2020;40(4):576-591
6. Willrich MAV, Braun KMP, Moyer AM, Jeffrey DH, Frazer-Abel A. Complement testing in the clinical laboratory. Crit Rev Clin Lab Sci. 2021 Nov;58(7):447-478. doi: 10.1080/10408363.2021.1907297
Report Available
1 to 3 daysMethod Name
Automated Liposome Lysis Assay